Home › Forums › Bug Reports › AC simulation plots frequency decade lower Tagged: AC-Simulation This topic has 1 reply, 2 voices, and was last updated 3 days, 21 hours ago by MarioK. Viewing 2 posts - 1 through 2 (of 2 total) Author Posts 2. May 2025 at 20:09 #8982 Garry GrutParticipant This schematic expects the freq. for Vout_dB to be approx. 1.58KHz. with inductor L1=0.1H. Note that V1’s phase is -90 degrees. The result however is 158 Hz for both uSimmics 5.8I and QucsStudio 4.3.1 If L1 is changed to 0.01H than we get 1.58KHz I did run the circuit in Qucs 0.0.19 and also in LTspice, which gave the expected frequency. How can I explain the decade difference between the simu;aters. Attachments: AC-sim-with-V1-phase-minus-90-degrees.sch 9. January 2026 at 23:13 #9177 MarioKParticipant I don’t really get your explanation. But compared to LTspice, the results are identical – under the condition that you use 1e3 or 1k (lower case letter!) as resistor values. The capital K used as an SI prefix is just ignored by uSimmics. Author Posts Viewing 2 posts - 1 through 2 (of 2 total) You must be logged in to reply to this topic.